  1. Von Duprin PS914-2RS

    Von Duprin PS914-2RS Power Supply

    $800.00

    Von Duprin PS914-2RS series power supply.
    The only power supply for use with Von Duprin EL exit devices such as the EL99 & EL9927.
    The regulated output power is field selectable for either 24VDC or 12VDC @ 4 amps.
    Standard power input 120/240 VAC.
    The PS914-2RS replaces the obsolete PS873-2 power supply.

    DOWNLOADS
    PS914 Data Sheet
    Installation Instructions

    Learn More
  2. Von Duprin PS902 Power Supply

    Von Duprin PS902 Power Supply

    $205.00

    Base Power Supply (2A @ 12/24 VDC field selectable).

    PS902 Works Von Duprin EL Lever Handles
    PS902-2RS (900-2RS Board) Works Von Duprin QEL Panic Devices

    2A @ 12/24 VDC output, field selectable with jumper.
    Low voltage DC, regulated and filtered output.
    Class 2 Rated power limited output.
    AC input and DC output monitoring circuit w/ LED indicators.
    Universal 120-240 VAC input.


    DOWNLOADS
    PS902 Data Sheet
    Installation Instructions

    Learn More
  3. Power Supply

    Power Supplies for First Choice MEL & EL Panic Devies

    $150.00

    Not Sure Which Power Supply you need?: Power Supply Selector

    1 Amp SINGLE Output - ( PSMEL1500-1 )Power Supply for MEL Motorized Latch Retraction capable of operating one (1) 1amp-24VDC panic hardware device.
    • In addition, an auxiliary power output shall provide power for accessory devices such as card
    readers, key-pads, REX PIRs, electronic timers, relays, etc.
    Single MEL Submittal
    Single MEL Install Manual

    1 Amp DUAL Output - ( PSMEL2000 ) Power Supply for MEL Motorized Latch Retraction capable of operating up to two (2) 1amp-24VDC panic hardware devices simultaneously
    • Each lock output shall have an adjustable relock delay timer
    • It shall control a pair of doors simultaneously or independently two doors
    • Relay for each output to trigger external relays, ADA push plate switches, etc.
    • Delayed follower relays shall control automatic door operators for doors that are always locked
    or for doors that are unlocked during the business day
    • Two un-switched auxiliary voltage outputs shall provide/remove power to the lock outputs when activated
    • A programmable FACP interface shall provide power/remove power to the lock outputs when activated
    • Shall have LED status indicators monitor AC, FACP status & for lock output wiring supervision
    • Intelligent logic shall provide protection against accidental shorting of lock outputs.
    Dual MEL Submittal
    Dual MEL Install Manual

    16 Amp SINGLE Output - ( PSEL1500 ) Power Supply for (solenoid) EL Electric Latch Retraction operates one (1) 16amp-24VDC panic hardware device.
    • It is designed to handle the high current surge panic hardware locking devices demand.
    • In addition, an auxiliary power output provides power for accessory devices such as card readers, key-pads, REX PIRs, electronic timers, relays, etc.
    Single EL Submittal
    Single EL Install Manual

    16 Amp DUAL Output - ( PSEL3000-2 )DUAL Power Supply for (solenoid) EL Electric Latch Retraction will operate up to two (2) 16amp-24VDC panic hardware devices simultaneously
    • It is designed to handle the high current surge panic hardware locking devices demand
    • Each lock output has an adjustable relock delay timer
    • It will control a pair of doors simultaneously or independently control two individual doors
    • It has a follower relay for each output to trigger external relays, ADA push plate switches, etc.
    • Delayed follower relays control automatic door operators for doors that are always locked or for doors that are unlocked during the business day
    • In addition, two un-switched auxiliary volt-age outputs are provided for powering card readers, keypads, REX PIRs, electronic timers, relays, etc.
    • A programmable FACP interface will either provide power or remove power to the lock outputs when activated.
    • LED status indicators are provided to monitor AC power, FACP status and for lock output wiring supervision.
    • Intelligent logic provides protection against accidental shorting of lock outputs.
    Dual EL Submittal
    Dual EL Install Manual

    Free Shipping On Power Supply When Purchased Along With A First Choice Panic Bar. (Lower 48 States)

    Learn More
  4. PS202

    Power Supplies for Command Access MLRK1-FAL17 MEL Kit

    $140.00

    Command Access PS202 Power Supply. This Will Power TWO (2) MLRK1 MEL Kit.

    PS202 - 110-120VAC input power supplies that deliver (2) amps @ 24VDC to (2) PTC fused outputs. (2) solid-state input triggers, protects system relays from shorts, grounds and surges. Its linear design makes it a perfect match for electric locks, motor driven exit devices, electric strikes, and mag locks.

    DOWNLOADS
    PS202 Cut Sheet
    PS202 Installation Manual