Search results for 'automatic door opener'
-
Sweep w/ Rain Drip
$14.00Door sweeps are surface applied to the face of a door.
They are commonly used on the exterior of out swing doors.
Sweeps Screw Applied
Aluminum/Vinyl Sweep
P1275A = Sweep Length is 36"
P1276A = Sweep Length is 42"P1277A = Sweep Length is 48"
Please call if you need a BRUSH insert instead.DOWNLOADS
Learn More
Sweep Cut Sheet -
Dorma BTS 80 Floor Concealed Closer - REPLACEMENT BODIES ONLY
$550.00REPLACEMENT BODIES ONLY
DOWNLOADS
Product Brochure
All floor-concealed door closers shall be DORMA BTS80 Series employing a cam and roller mechanism. The closers shall be capable of controlling interior or exterior doors weighing up to 660 pounds and measuring up to 4'-0" wide exterior and 4'-6" interior. The closers will have a selectable multipoint hold open between approximately 75º and 175º. The closers will have selectable delayed action to allow delayed closing from 175º to 75º. The closers will have a mechanical backcheck at approximately 70º. Dual valve adjustment will provide a controlled closing speed from approximately 175º opening range, even in cold temperature conditions. The closer will provide adjustment within the cement case to allow lateral and longitudinal adjustment of 1/4" and vertical height adjustment of 5/32". Field interchangeable spindles will be available to provide bottom door clearances ranging from 5/16" to 2-5/16".Available in Ansi 3, Ansi 4, and Ansi 6 - bodies only
Learn More
Ansi 3 = Up to a 3'-0" Exterior Door or 3'-6" Interior Door
Ansi 4 = Up to a 3'-6" Exterior Door or 4'-0" Interior Door
Ansi 6 = Up to a 4' Exterior Door or 4'-6" Interior Door -
Dorma RTS 88 Overhead Concealed Closer - REPLACEMENT BODIES ONLY AND 11/16" SPINDLE
$215.00REPLACEMENT BODIES ONLY
NOTE: Aroyan stocks 11/16" (+5mm) spindles instead of 1/2" at NO EXTRA CHARGEAroyan only stocks the Size 3 Body with 11/16 (extended 5mm) Spindle - All other configurations are factory order.
The RTS88 is designed to give lasting, dependable service where surface applied units and other types of closers are not suitable, or would interfere with the architectural design. It can be easily installed in wood, aluminum, or hollow metal doors and frames, for single and double-acting doors.
Size 2 = Up to a 2'-6" Exterior Door or 3'-0" Interior Door
Size 3= Up to a 3'-0" Exterior Door or 3'-6" Interior Door
Size 4 = Up to a 3'-6" Exterior Door or 4' Interior Door
Size BFI = Interior Door 5lb max opening force for ADA - Available in 105 degrees only.
Size BFE = Exterior Door 8.5lb max opening force for ADA - Available in 105 degrees only.
DOWNLOADS
Product Manual* Closer Sizes 2, 4, BFI, BFE have at least one week lead time from the factory.
Learn More
* All 1/2" Spindle models have at least one week lead time from the factory. -
LCN 4040XP REG Slide Arm Closer
$0.00The 4040XP Series is LCN’s most durable surface-mounted heavy-duty closer, designed for the most demanding high-use-and-abuse applications.
It meets ANSI/BHMA A156.4 Grade 1 standards and ADA reduced opening force requirements.
This closer is cUL listed and UL listed for self-closing doors without hold-open and boasts a 30-year limited warranty.LCN peel-n-stick templates assure quick and accurate installation, and the patented LCN Green Dial takes the guesswork out of spring force adjustments.
Learn More
DOWNLOADS
Catalog Section
Pull Side Installation Instructions -
Adams Rite 4902 Strike Plate
$10.00Adams Rite 4902-01 - Flat For Frame Side - Includes molded black plastic dust box and steel mounting plate
Adams Rite 4902-02 - radiused strike plate, for the nose of the opposite door when latching pairs. - Includes molded black plastic dust box and steel mounting plateDOWNLOADS
Learn More
Data Sheet
Installation Template -
Schlage AL80BD SAT 626 Storeroom Door Lever Set
Regular Price: $200.00
Special Price $100.00
The Schlage AL80BD Storeroom Lever is perfect for medical, office, hotel, public buildings, religious, multi-family, retail, and government facilities. Both indoor and outdoor applications
AL series has been discontinued and replaced by the ALX
One left - get it on a DISCOUNTED speical price!
Schlage AL80BD SAT 626 Storeroom Door Lever Set without Small Format Interchangeable Core
- Function Entrance
- Grade 2
- Finish: Satin Chrome - 626
- Handing Reversible
- Backset: 2-3/4"
- Latch Type: Square Corner
- Strike: ANSI Strike 10-025
- Door Thickness 1-3/8" to 1-7/8"
- ANSI Certification: Meets or exceeds A156.2 Series 4000, Grade 2 strength and operational requirements.DOWNLOADS
AL-Series Catalog
AL-Service Manual
AL-Installation Instructions
Learn More -
SDC PT-5 Concealed Power Transfer Device
$50.00Heavy Duty Power Transfer Device
Concealed Mortise Mount
UL Listed Miscellaneous Fire Door Accessory
UL 10C Positive Pressure Compliant
UBC 7-2 Fire Test for Door Assemblies Compliant.Chrome Finish Only.
DOWNLOADS
Learn More
Data Sheet -
ADA1015P Hardwire Kit - Transformer, Armored Door Cord, 50' of Cable ADAEZ / Noton 5800
$210.00HARDWARE KIT – Enables operator to be used 100% automatically plus may engage Power Close and Push-N-Go Features – includes -Transformer, Armored Door Cord, End Links. Learn More -
ADA1007P Battery Assembly ADAEZ / Norton 5800
$160.00Battery Assembly for ADAEZ / Norton 5800 1007P
Learn More
Backward compatible with previous closer assemblies.
On-Off switch on the body.
Replacement 24-volt Lithium-ion Battery provides reserve energy to open doors up to 2000 times with no regeneration. -
Power Supplies for First Choice MEL & EL Panic Devies
$150.00Not Sure Which Power Supply you need?: Power Supply Selector
1 Amp SINGLE Output - ( PSMEL1500-1 )Power Supply for MEL Motorized Latch Retraction capable of operating one (1) 1amp-24VDC panic hardware device.
• In addition, an auxiliary power output shall provide power for accessory devices such as card
readers, key-pads, REX PIRs, electronic timers, relays, etc.
Single MEL Submittal
Single MEL Install Manual1 Amp DUAL Output - ( PSMEL2000 ) Power Supply for MEL Motorized Latch Retraction capable of operating up to two (2) 1amp-24VDC panic hardware devices simultaneously
• Each lock output shall have an adjustable relock delay timer
• It shall control a pair of doors simultaneously or independently two doors
• Relay for each output to trigger external relays, ADA push plate switches, etc.
• Delayed follower relays shall control automatic door operators for doors that are always locked
or for doors that are unlocked during the business day
• Two un-switched auxiliary voltage outputs shall provide/remove power to the lock outputs when activated
• A programmable FACP interface shall provide power/remove power to the lock outputs when activated
• Shall have LED status indicators monitor AC, FACP status & for lock output wiring supervision
• Intelligent logic shall provide protection against accidental shorting of lock outputs.
Dual MEL Submittal
Dual MEL Install Manual16 Amp SINGLE Output - ( PSEL1500 ) Power Supply for (solenoid) EL Electric Latch Retraction operates one (1) 16amp-24VDC panic hardware device.
• It is designed to handle the high current surge panic hardware locking devices demand.
• In addition, an auxiliary power output provides power for accessory devices such as card readers, key-pads, REX PIRs, electronic timers, relays, etc.
Single EL Submittal
Single EL Install Manual16 Amp DUAL Output - ( PSEL3000-2 )DUAL Power Supply for (solenoid) EL Electric Latch Retraction will operate up to two (2) 16amp-24VDC panic hardware devices simultaneously
• It is designed to handle the high current surge panic hardware locking devices demand
• Each lock output has an adjustable relock delay timer
• It will control a pair of doors simultaneously or independently control two individual doors
• It has a follower relay for each output to trigger external relays, ADA push plate switches, etc.
• Delayed follower relays control automatic door operators for doors that are always locked or for doors that are unlocked during the business day
• In addition, two un-switched auxiliary volt-age outputs are provided for powering card readers, keypads, REX PIRs, electronic timers, relays, etc.
• A programmable FACP interface will either provide power or remove power to the lock outputs when activated.
• LED status indicators are provided to monitor AC power, FACP status and for lock output wiring supervision.
• Intelligent logic provides protection against accidental shorting of lock outputs.
Dual EL Submittal
Dual EL Install ManualFree Shipping On Power Supply When Purchased Along With A First Choice Panic Bar. (Lower 48 States)
Learn More