The 5700 series operator comprises three components making it an easy solution for medium traffic doors that need basic operator functionality. While simple to install and use, this operator consists of a 1600 series door closer with a proven history of dependability.
Universal Non-Handed, Push & Pull Mounting, Includes Wireless Push Buttons & 18" Power Cord to Plug Directly Into a120v Outlet
Note: The operator is shipped as a PUSH unit and includes instructions to convert to pull in the field.
Norton 5740K3 Complete Kit Includes:
5700 Operator
Cover
7701-1A Push Arm Assembly
5710-1 Pull Arm Assembly
(2) ADA1019-1 Push Buttons
(2) 548 Transmitters
539 Reciever 5700PC
18" Power cord
DOWNLOADS
Installation and Operating Instructions Using Power Cord- Push & Pull Mount
Installation and Operating Instructions Hardwire- Push & Pull Mount
Push To Pull Conversion Instructions
Wiring Instructions
Catalog/Brochure
Warranty
Looking for the Touchless Norton 700 Actuators?
Features:
Ease of installation and setup
Simple instructions
Application versatility and ease of adjustment; push or pull side mounting units available
Operates as a mechanical surface closer during close cycles, when the door is opened manually or if power is turned off; quiet operation
Spring force provides the feel of a normal manual door closer; the door can be opened manually if desired
Functions:
Norton® 1601/1601BF series door closer
Non-Handed
Unit Activation Options: wall switches, motion sensor, radio frequency device
End-User On/Off Switch
Hold Open options; 0-30 seconds (5 seconds minimum required for ADA and ANSI/BHMA A156.19)
Obstruction Detection: the motor stops if the door is obstructed during an opening; the door closes under manual spring force (not to exceed 15lbf)
"Push and Close"; allows the operator to skip the hold-open time when it is not necessary or required
Adjustable door sensitivity
Overload Safety Shut-Off - after two minutes of receiving a door activation signal, the inverter will time out and close the door; prevents motor/inverter damage
Motor Start Delay for Locking Hardware - 0-5 second delay to allow locking hardware to release first
Onboard power supply for accessories: 24VDC (1.1A)
Typical Applications:
Hospitals
Behavioral Health
X-Ray Room
Patient Room
Colleges or Universities
Dorm Rooms
Strip Mall
Main Entrance Doors
Electrical Data:
Power Input; 120 VAC, 60Hz
Current Draw: 0.9A
Auxiliary Output: 24VDC @ 1.1A
Relay Output: 0.9A
Normally Open/Normally Closed (jumper) for electric strike function
Certifications:
C-UL US listed for use on fire and smoke barrier doors
Meets ADA requirements
ANSI/BHMA A156.19 certified
Meets ANSI/BHMA A156.4 requirements
2-year limited warranty